Table 1. CAN/ULC-S710.1-11 technical requirements- Class 1
Property Requirements
Min. Max.
Air permeance (L/(m2•s) at 75 Pa) – 0.02
Open cell content (%) – 98
Density (kg/m3) 8 –
Dimensional stability Volume change (%) at −20°C – ±5
Volume change (%) at 70°C , 97 ±3% RH – ±15
Durability performance: air permeance per 1-m length after aging on client specified substrates (L/s at 75 Pa) – 0.05
Elongation at break (%) 5 –
Initial thermal resistance (without captive blowing agent) at 25 mm thick (m2•°K/W) 0.55 –
Surface burning characteristics Class 1 – flame spread – 25
Smoke developed classification Class 1 – 50
Tack-free time (min) at 23 ° C, 50% RH – 20
Tensile strength (kPa) 25 –
Volatile organic compounds (time to reach maximum allowable limit levels) (h) 1 –
Yield (L/100g) Report value –