Allowable Compressive and Tensile Loads for the Proposed Auger-installed Steel PileFootnote (1) Footnote (2) Footnote (3)
Applied Torque

Allowable Loads

Compression

Tension

N·m

lbf

kN

lbs

kN

lbs

    678

   500

 11.2

 2 500

  8.8

 2 000

 1 356

 1 000

 22.4

 5 000

 17.6

 4 000

 2 034

 1 500

 33.6

 7 500

 26.4

 6 000

 2 712

 2 000

 44.7

10 000

 35.3

 8 000

 3 390

 2 500

 55.9

12 500

 44.1

10 000

 4 068

 3 000

 67.1

15 000

 52.9

12 000

 4 746

 3 500

 78.3

17 500

 61.7

14 000

 5 424

 4 000

 89.5

20 000

 70.5

16 000

 6 102

 4 500

100.7

22 500

 79.3

18 000

 6 780

 5 000

111.9

25 000

 88.1

20 000

 7 458

 5 500

123.1

27 500

 97.0

22 000

 8 136

 6 000

134.2

30 000

105.8

24 000

 8 814

 6 500

145.4

32 500

114.6

26 000

 9 492

 7 000

156.6

35 000

123.4

28 000

10 170

 7 500

167.8

37 500

132.2

30 000

10 848

 8 000

179.0

40 000

141.0

32 000

11 526

 8 500

190.2

42 500

149.8

34 000

12 204

 9 000

201.4

45 000

158.7

36 000

12 882

 9 500

212.6

47 500

167.5

38 000

13 560

10 000

223.7

50 000

176.3

40 000