Language selection

Search

Content page

From [Institution name]

Galvanized and Aluminum-Zinc Alloy Coated Steel Base Material Requirements and Performance Data

Property

Requirement

Result

Thickness (mm)

≥ 0.33

0.42

Thickness of aluminum-zinc coating (g/m2)

≥ 150

171

Flexibility

No flaking or micro-cracking

Pass

Humidity resistance

No formation of blisters

Pass

Salt spray resistance

≥ 7 rating

Pass

Durability

Slight colour change; not greater than No. 8 degree of chalking; no flaking or cracking

Pass

Results of Testing the Wind Uplift of "GRANITE-RIDGE Shingle"Footnote (1)

Pressure (kPa)

Requirement

Result

1.4

No evidence of deformation, permanent damage or failure

Pass

2.9

No evidence of deformation, permanent damage or failure

Pass

4.3

No evidence of deformation, permanent damage or failure

Pass

9.1Footnote (2)

No evidence of deformation, permanent damage or failure

Plywood fastener pull-through

Results of Testing the Dynamic Pressure Water Infiltration Resistance of "GRANITE-RIDGE Shingle"Footnote (1)

Wind SpeedFootnote (2) (km/h)

Simulated Rainfall (L/m2·min)

Duration (min)

Requirement

Result

50

3.4

15

No leakage or damage

Pass

110

3.4

15

No leakage or damage

Pass

140

3.4

15

No leakage or damage

Pass

170

3.4

5

No leakage or damage

Pass

Results of Testing the Granule Adhesion of the Products

Sample

Average Initial Weight (g)

Average Final Weight (g)

Average Weight Loss (g)

Colour quartz

65.074

64.985

0.096

Roofing granule

63.88

63.71

0.176