Results of Testing the Wind Uplift of "MetroROMAN® TILE"

Pressure (kPa)

Requirement

ResultFootnote (1)

3

No evidence of deformation, permanent damage or failure

Pass

3.8

No evidence of deformation, permanent damage or failure

Pass

4.5

No evidence of deformation, permanent damage or failure

Pass

5.2

No evidence of deformation, permanent damage or failure

Pass

5.9

No evidence of deformation, permanent damage or failure

Pass

6.6

No evidence of deformation, permanent damage or failure

Pass

7.3

No evidence of deformation, permanent damage or failure

Pass

8.1

No evidence of deformation, permanent damage or failure

Pass

8.8

No evidence of deformation, permanent damage or failure

Pass

9.0Footnote (2)

Batten fastener pull-through

Results of Testing the Dynamic Pressure Water Infiltration Resistance of "MetroROMAN® TILE"

Wind Speed (km/h)

Simulated Rainfall (L/m2•min)

Duration (min)

Requirement

ResultFootnote (1)

50

3.7

15

No leakage or damage

Pass

110

3.7

15

No leakage or damage

Pass

140

3.7

15

No leakage or damage

Pass

170

3.7

5

No leakage or damage

Pass

Result of Testing the Salt Spray Resistance

Property

Test Method

Result

Stone coated steel

ASTM B 117

Pass

Results of Testing the Granule Adhesion of "MetroSHAKE II®"

Property

Test Method

Result

Granule adhesion

ASTM D 4977