Content page
From [Institution name]
RSI (m2·K/W) |
Minimum Installed Density (kg/m3) |
Minimum Thickness (mm) |
Minimum Mass per Area (kg/m2) |
Maximum Coverage per Bag (m2) |
Minimum Bags per Area (100 m2) |
---|---|---|---|---|---|
2.5 |
24.0 |
89 |
2.14 |
6.4 |
15.7 |
2.6 |
28.8 |
89 |
2.56 |
5.3 |
18.8 |
RSI (m2·K/W) |
Minimum Installed Density (kg/m3) |
Minimum Thickness (mm) |
Minimum Mass per Area (kg/m2) |
Maximum Coverage per Bag (m2) |
Minimum Bags per Area (100 m2) |
---|---|---|---|---|---|
4.1 |
24.0 |
140 |
3.36 |
4.1 |
24.7 |
4.2 |
28.8 |
140 |
4.03 |
3.4 |
29.6 |
Property |
Requirement |
Result |
---|---|---|
Insulation |
Meets requirements of CAN/ULC-S702-09 |
Pass |
Property |
Requirement |
Result |
---|---|---|
Consistent density in wall cavity |
Within 10% of the design density |
Pass |
Thermal resistance |
≥ 18.5 m2·KW−1/m |
Pass |
Moisture content of insulation within the stud space |
No adverse effect on the relative humidity within the stud cavity or on the moisture content in the stud |
Pass |