Language selection

Search

Content page

From [Institution name]

Application and Coverage Requirements for the Product

RSI (m2·K/W)

Cavity Depth (mm)

Applied Density (kg/m3)

Bag Usage (Bags/100 m2)

Maximum Coverage (m2/Bag)

2.5

89

24.0

14.7

6.8

3.9

140

24.0

23.2

4.3

5.1

184

24.0

30.5

3.3

6.5

235

24.0

38.9

2.6

2.7

89

30.4

18.7

5.4

4.1

140

30.4

29.4

3.4

5.5

184

30.4

38.6

2.6

7.0

235

30.4

49.3

2.0

Results of Testing the Moisture Content and Density of the Product

Specimen

Moisture Content (%)

Density (kg/m3)

A

15.2

31.56

B

19.0

34.14

C

12.5

30.75

Average

15.6

32.15

Results of Testing the Specimen Density and Thermal Resistance of the Product

Specimen

Specimen Density (kg/m3)

Corresponding Thermal Resistance (m2·K/W)

A

30.56

4.27

B

31.00

4.31

C

30.86

4.36

Average

30.81

4.31

Results of Testing the Fire Protection Requirements of the Product

Property

Result

Smoulder resistance

No evidence of flaming combustion during the tests

Flame-spread classification (FSC)

5

Smoke-developed classification (SDC)

5