Content page
From [Institution name]
RSI (m2 ·K)/W |
Cavity Depth (mm) for 2.35 m Cavity Height |
Applied Density (kg/m3 ) |
Number of Cavities Filled Per 14.1-kg Bag |
---|---|---|---|
2.58 |
89 (at 406 mm o.c.) |
32 |
5.7 |
4.07 |
140 (at 406 mm o.c.) |
32 |
3.6 |
4.07 |
140 (at 610 mm o.c.) |
32 |
2.3 |
Property |
Unit |
Requirement |
Result |
|
---|---|---|---|---|
Bulge |
38 mm × 89 mm studs at 406 mm o.c. |
mm |
13 |
Pass |
38 mm × 140 mm studs at 406 mm o.c. |
mm |
13 |
Pass |
|
38 mm × 140 mm studs at 610 mm o.c. |
mm |
13 |
Pass |
|
Design density |
38 mm × 89 mm studs at 406 mm o.c. |
kg/m3 |
> 25 or proponent's design density |
Pass |
38 mm × 140 mm studs at 406 mm o.c. |
kg/m3 |
> 25 or proponent's design density |
Pass |
|
38 mm × 140 mm studs at 610 mm o.c. |
kg/m3 |
> 25 or proponent's design density |
Pass |
|
Density deviation from each stud space |
38 mm × 89 mm studs at 406 mm o.c. |
% |
± 10% of design density |
Pass |
38 mm × 140 mm studs at 406 mm o.c. |
% |
± 10% of design density |
Pass |
|
38 mm × 140 mm studs at 610 mm o.c. |
% |
± 10% of design density |
Pass |
|
Thermal resistance at 150 mm |
38 mm × 89 mm studs at 406 mm o.c. |
(m2·K)/W |
> 3.6 |
Pass |
38 mm × 140 mm studs at 406 mm o.c. |
(m2·K)/W |
> 3.6 |
Pass |
|
38 mm × 140 mm studs at 610 mm o.c. |
(m2·K)/W |
> 3.6 |
Pass |