Content page
From [Institution name]
Property |
Unit |
Requirement |
Result |
---|---|---|---|
Density |
kg/m3 |
≥ 6.8 |
17 |
Thermal resistance for 25-mm thickness |
m2∙°C/W |
Report value |
0.75 |
Water vapour transmission for 25-mm thickness |
ng/(Pa·s·m2) |
≥ 800 (Type 2) |
1 175 (average of 3 tests) |
Water absorption |
% |
< 5 (Type 2) |
1.39 (average of 4 tests) |
Dimensional changes when exposed to 80°C and ambient RH |
% volumetric |
Min. –15 Max. +10 |
–9.0 (average of 3 tests) |
Dimensional changes when exposed to 70°C and 97 ± 3% RH |
% volumetric |
Min. –15 Max. +14 |
–2.3 (average of 3 tests) |
Dimensional changes when exposed to -29°C and ambient RH |
% volumetric |
Min. –1 – |
0.3 (average of 3 tests) |
Emissions – time to occupancy |
– |
Pass |
Property |
Requirement |
Result |
---|---|---|
Flame-spread rating Footnote (3) (CAN/ULC-S102 and CAN/ULC-S127) |
Report value |
174 |
Smoke development |
Report value |
495 |