Content page
From [Institution name]
Property |
Unit |
Requirement |
Result |
|
---|---|---|---|---|
Density |
kg/m3 |
> 6.8 |
6.8 |
|
Thermal resistance at 25-mm thickness |
m2·°C/W |
Report value |
0.61 |
|
Water vapour transmission for 50-mm thickness |
ng/(Pa·s·m2) |
> 1400 (Type 1) |
1 580 |
|
Water absorption |
% |
Report value |
17.4 |
|
Dimensional changes when exposed to:
|
80°C and ambient RH |
% volumetric |
min. –15 max. +10 |
0 |
Dimensional changes when exposed to: |
70°C and 97 ± 3% RH |
% volumetric |
min. –15 max. +14 |
–0.1 |
Dimensional changes when exposed to: |
–29°C and ambient RH |
% volumetric |
min. –1 – |
–0.1 |
Emissions: time to occupancy |
|
See Note Footnote (1) |
Pass |
Property |
Requirement |
Result |
---|---|---|
Flame-spread rating (CAN/ULC-S102 and CAN/ULC-S127) |
Report value |
315 |
Smoke development |
Report value |
195 |