Content page
From [Institution name]
Property |
Unit |
Requirement |
Result |
---|---|---|---|
Density |
kg/m3 |
≥ 6.8 |
7.0 |
Thermal resistance at 25-mm thickness |
m2·°C/W |
Report value |
0.59 |
Water vapour transmission for 50-mm thickness |
ng/(Pa·s·m2) |
≥ 1 400 |
1 548 |
Water absorption |
% |
Report value |
21 |
Dimensional changes when exposed to 80° C and ambient RH |
% volumetric |
Min. –15 |
–3.1 |
% volumetric |
Max. +10 |
–3.1 |
|
Dimensional changes when exposed to 70°C and 97 ± 3% RH |
% volumetric |
Min. –15 |
–5.2 |
% volumetric |
Max. +14 |
–5.2 |
|
Dimensional changes when exposed to –29°C and ambient RH |
% volumetric |
Min. –1 |
–0.7 |
% volumetric |
— |
–0.7 |
|
Emissions – time to occupancy |
— |
Pass |
Property |
Requirement |
Result |
---|---|---|
Flame-spread rating (CAN/ULC-S127) |
Report value |
420 |
Smoke development (CAN/ULC-S102) |
Report value |
245 |