Content page
From [Institution name]
Property |
Unit |
Requirement |
Declared Value |
Result |
---|---|---|---|---|
Thickness, average |
mm |
≥ (Declared value) and ≤ (Declared value + 0.025) |
0.25 |
0.25 |
Width |
mm |
≥ (Declared width) and ≤ (Declared width + 0.8) |
88.9 |
89.4 |
Width |
mm |
101.6 |
102.4 |
|
Width |
mm |
152.4 |
152.8 |
|
Width |
mm |
228.6 |
229.0 |
|
Length |
% |
≥ (Declared length) and ≤ (Declared length + 1%) |
27.4 |
28 |
Property |
Unit |
Requirement |
Result |
---|---|---|---|
Tensile breaking strength, MDFootnote (1) |
N/m |
Report value |
3 523 |
Tensile breaking strength, CMDFootnote (2) |
N/m |
Report value |
3 209 |
Elongation, average, MD |
% |
≥ 400 |
1 033 |
Elongation, average, CMD |
% |
≥ 400 |
1 037 |
Load strain, MD |
– |
800 000 |
3 649 905 |
Load strain, CMD |
– |
800 000 |
3 335 020 |
Nail sealability |
– |
No water penetration |
Pass |
Property |
Unit |
Requirement |
Result |
---|---|---|---|
Water resistance |
– |
No water seepage |
Pass |
Pliability at manufacturer’s minimum specified installation temperature (−20°C) |
– |
No cracking and no loss of adhesion |
Pass |
Bond separation (flagging) |
mm |
≤ 2 |
≤ 1 |
Property |
Unit |
Requirement |
Result |
---|---|---|---|
Tensile breaking strength, MDFootnote (1) |
% of original |
≥ 75 |
78 (2 760.4 N/m) |
Tensile breaking strength, CMDFootnote (2) |
% of original |
≥ 75 |
77 (2 466.8 N/m) |
Elongation, average, MD |
% |
≥ 400 |
999 |
Elongation, average, CMD |
% |
≥ 400 |
953 |
Load strain, MD |
– |
800 000 |
2 761 139 |
Load strain, CMD |
– |
800 000 |
2 353 490 |
Water resistance |
– |
No water seepage |
Pass |
Pliability at low temperature (−20°C) |
– |
Pass |
Pass |
Property |
Substrate |
Unit |
Requirement |
Result |
---|---|---|---|---|
Peel Adhesion |
PVC |
N/m |
≥ 200 |
569.5 |
Window wood, pine |
N/m |
≥ 200 |
680.4 |
|
Anodized aluminum |
N/m |
≥ 200 |
618.8 |
|
Fibre-reinforced plastic (FRP) |
N/m |
≥ 200 |
626.5 |
|
Framing lumber, spruce |
N/m |
≥ 200 |
641.1 |
|
Non-adherent side of the tape backing |
N/m |
≥ 200 |
461.2 |
|
Unexposed plane "Foamular®" XPS |
N/m |
≥ 200 |
631.6 |
|
UV-exposed plane "Foamular®" XPSFootnote (1) |
N/m |
≥ 200 |
519.9 |
Property |
Substrate |
Unit |
Requirement |
Result |
---|---|---|---|---|
Shear Adhesion |
PVC |
Rating 1 to 4Footnote (2) |
Rating 1 or 2 |
Rating 1 |
Window wood, pine |
Rating 1 to 4 |
Rating 1 or 2 |
Rating 1 |
|
Anodized aluminum |
Rating 1 to 4 |
Rating 1 or 2 |
Rating 1 |
|
Fibre-reinforced plastic (FRP) |
Rating 1 to 4 |
Rating 1 or 2 |
Rating 1 |
|
Framing lumber, spruce |
Rating 1 to 4 |
Rating 1 or 2 |
Rating 1 |
|
Non-adherent side of the tape backing |
Rating 1 to 4 |
Rating 1 or 2 |
Rating 1 |
|
Unexposed plane "Foamular®" XPS |
Rating 1 to 4 |
Rating 1 or 2 |
Rating 1 |
|
UV-exposed plane "Foamular®" XPSFootnote (1) |
Rating 1 to 4 |
Rating 1 or 2 |
Rating 1 |
Property |
Substrate |
Unit |
Requirement |
Result |
---|---|---|---|---|
Peel Adhesion |
PVC |
N/m |
≥ 200 |
352.4 |
Window wood, pine |
N/m |
≥ 200 |
267.0 |
|
Anodized aluminum |
N/m |
≥ 200 |
329.8 |
|
Fibre-reinforced plastic (FRP) |
N/m |
≥ 200 |
335.2 |
|
Framing lumber, spruce |
N/m |
≥ 200 |
212.7 |
|
Non-adherent side of the tape backing |
N/m |
≥ 200 |
294.8 |
|
Unexposed plane "Foamular®" XPS |
N/m |
≥ 200 |
359.8 |
|
UV-exposed plane "Foamular®" XPSFootnote (1) |
N/m |
≥ 200 |
321.8 |
|
Shear Adhesion |
PVC |
Rating 1 to 4Footnote (2) |
Rating 1 or 2 |
Rating 1 |
Window wood, pine |
Rating 1 to 4 |
Rating 1 or 2 |
Rating 1 |
|
Anodized aluminum |
Rating 1 to 4 |
Rating 1 or 2 |
Rating 1 |
|
Fibre-reinforced plastic (FRP) |
Rating 1 to 4 |
Rating 1 or 2 |
Rating 1 |
|
Framing lumber, spruce |
Rating 1 to 4 |
Rating 1 or 2 |
Rating 1 |
|
Non-adherent side of the tape backing |
Rating 1 to 4 |
Rating 1 or 2 |
Rating 1 |
|
Unexposed plane "Foamular®" XPS |
Rating 1 to 4 |
Rating 1 or 2 |
Rating 1 |
|
UV-exposed plane "Foamular®" XPSFootnote (1) |
Rating 1 to 4 |
Rating 1 or 2 |
Rating 1 |
Property |
Substrate |
Unit |
Requirement |
Result |
---|---|---|---|---|
Peel Adhesion |
PVC |
N/m |
≥ 200 |
809.5 |
Window wood, pine |
N/m |
≥ 200 |
895.7 |
|
Anodized aluminum |
N/m |
≥ 200 |
813.6 |
|
Fibre-reinforced plastic (FRP) |
N/m |
≥ 200 |
916.0 |
|
Framing lumber, spruce |
N/m |
≥ 200 |
936.5 |
|
Non-adherent side of the tape backing |
N/m |
≥ 200 |
625.8 |
|
Unexposed plane "Foamular®" XPS |
N/m |
≥ 200 |
547.3 |
|
UV-exposed plane "Foamular®" XPSFootnote (1) |
N/m |
≥ 200 |
491.7 |
|
Shear Adhesion |
PVC |
Rating 1 to 4Footnote (2) |
Rating 1 or 2 |
Rating 1 |
Window wood, pine |
Rating 1 to 4 |
Rating 1 or 2 |
Rating 1 |
|
Anodized aluminum |
Rating 1 to 4 |
Rating 1 or 2 |
Rating 1 |
|
Fibre-reinforced plastic (FRP) |
Rating 1 to 4 |
Rating 1 or 2 |
Rating 1 |
|
Framing lumber, spruce |
Rating 1 to 4 |
Rating 1 or 2 |
Rating 1 |
|
Non-adherent side of the tape backing |
Rating 1 to 4 |
Rating 1 or 2 |
Rating 1 |
|
Unexposed plane "Foamular®" XPS |
Rating 1 to 4 |
Rating 1 or 2 |
Rating 1 |
|
UV-exposed plane "Foamular®" XPSFootnote (1) |
Rating 1 to 4 |
Rating 1 or 2 |
Rating 1 |
Property |
Substrate |
Unit |
Requirement |
Result |
---|---|---|---|---|
Peel Adhesion |
PVC |
N/m |
≥ 200 |
567.0 |
Window wood, pine |
N/m |
≥ 200 |
568.2 |
|
Anodized aluminum |
N/m |
≥ 200 |
621.2 |
|
Fibre-reinforced plastic (FRP) |
N/m |
≥ 200 |
660.5 |
|
Framing lumber, spruce |
N/m |
≥ 200 |
713.1 |
|
Non-adherent side of the tape backing |
N/m |
≥ 200 |
468.5 |
|
Unexposed plane "Foamular®" XPS |
N/m |
≥ 200 |
681.9 |
|
UV-exposed plane "Foamular®" XPSFootnote (1) |
N/m |
≥ 200 |
565.3 |
|
Shear Adhesion |
PVC |
Rating 1 to 4Footnote (2) |
Rating 1 or 2 |
Rating 1 |
Window wood, pine |
Rating 1 to 4 |
Rating 1 or 2 |
Rating 1 |
|
Anodized aluminum |
Rating 1 to 4 |
Rating 1 or 2 |
Rating 1 |
|
Fibre-reinforced plastic (FRP) |
Rating 1 to 4 |
Rating 1 or 2 |
Rating 1 |
|
Framing lumber, spruce |
Rating 1 to 4 |
Rating 1 or 2 |
Rating 1 |
|
Non-adherent side of the tape backing |
Rating 1 to 4 |
Rating 1 or 2 |
Rating 1 |
|
Unexposed plane "Foamular®" XPS |
Rating 1 to 4 |
Rating 1 or 2 |
Rating 1 |
|
UV-exposed plane "Foamular®" XPSFootnote (1) |
Rating 1 to 4 |
Rating 1 or 2 |
Rating 1 |
Property |
Substrate |
Unit |
Requirement |
Result |
---|---|---|---|---|
Peel Adhesion |
PVC |
N/m |
≥ 200 |
681.2 |
Window wood, pine |
N/m |
≥ 200 |
692.1 |
|
Anodized aluminum |
N/m |
≥ 200 |
678.7 |
|
Fibre-reinforced plastic (FRP) |
N/m |
≥ 200 |
703.9 |
|
Framing lumber, spruce |
N/m |
≥ 200 |
723.0 |
|
Non-adherent side of the tape backing |
N/m |
≥ 200 |
615.4 |
|
Unexposed plane "Foamular®" XPS |
N/m |
≥ 200 |
585.1 |
|
UV-exposed plane "Foamular®" XPSFootnote (2) |
N/m |
≥ 200 |
508.5 |
|
Shear Adhesion |
PVC |
Rating 1 to 4Footnote (3) |
Rating 1 or 2 |
Rating 2 |
Window wood, pine |
Rating 1 to 4 |
Rating 1 or 2 |
Rating 2 |
|
Anodized aluminum |
Rating 1 to 4 |
Rating 1 or 2 |
Rating 2 |
|
Fibre-reinforced plastic (FRP) |
Rating 1 to 4 |
Rating 1 or 2 |
Rating 2 |
|
Framing lumber, spruce |
Rating 1 to 4 |
Rating 1 or 2 |
Rating 1 |
|
Non-adherent side of the tape backing |
Rating 1 to 4 |
Rating 1 or 2 |
Rating 1 |
|
Unexposed plane "Foamular®" XPS |
Rating 1 to 4 |
Rating 1 or 2 |
Rating 2 |
|
UV-exposed plane "Foamular®" XPSFootnote (2) |
Rating 1 to 4 |
Rating 1 or 2 |
Rating 2 |
Property |
Substrate |
Unit |
Requirement |
Result |
---|---|---|---|---|
Peel Adhesion |
PVC |
% of original |
≥ 75 |
158 (675.2 N/m) |
Window wood, pine |
% of original |
≥ 75 |
151 (771.1 N/m) |
|
Anodized aluminum |
% of original |
≥ 75 |
154 (715.7 N/m) |
|
Fibre-reinforced plastic (FRP) |
|
≥ 75 |
170 (798.3 N/m) |
|
Framing lumber, spruce |
% of original |
≥ 75 |
162 (775.0 N/m) |
|
Unexposed plane "Foamular®" XPS |
% of original |
≥ 75 |
135 (639.2 N/m) |
|
UV-exposed plane "Foamular®" XPSFootnote (1) |
% of original |
≥ 75 |
133 (519.2 N/m) |
|
Shear Adhesion |
PVC |
Rating 1 to 4Footnote (2) |
Rating 1 or 2 |
Rating 1 |
Window wood, pine |
Rating 1 to 4 |
Rating 1 or 2 |
Rating 1 |
|
Anodized aluminum |
Rating 1 to 4 |
Rating 1 or 2 |
Rating 1 |
|
Fibre-reinforced plastic (FRP) |
Rating 1 to 4 |
Rating 1 or 2 |
Rating 1 |
|
Framing lumber, spruce |
Rating 1 to 4 |
Rating 1 or 2 |
Rating 1 |
|
Non-adherent side of the tape backing |
Rating 1 to 4 |
Rating 1 or 2 |
Rating 1 |
|
Unexposed plane "Foamular®" XPS |
Rating 1 to 4 |
Rating 1 or 2 |
Rating 1 |
|
UV-exposed plane "Foamular®" XPSFootnote (1) |
Rating 1 to 4 |
Rating 1 or 2 |
Rating 1 |
Substrate |
Unit |
Requirement |
Result |
---|---|---|---|
PVC |
N/m |
≥ 200 |
585.0 |
Window wood, pine |
N/m |
≥ 200 |
671.3 |
Anodized aluminum |
N/m |
≥ 200 |
682.5 |
Fibre-reinforced plastic (FRP) |
N/m |
≥ 200 |
726.1 |
Framing lumber, spruce |
N/m |
≥ 200 |
671.3 |
Non-adherent side of the tape backing |
N/m |
≥ 200 |
451.6 |
Unexposed plane "Foamular®" XPS |
N/m |
≥ 200 |
611.3 |
UV-exposed plane "Foamular®" XPSFootnote (1) |
N/m |
≥ 200 |
379.5 |
Substrate |
Unit |
Requirement |
Result |
---|---|---|---|
Nail sealability |
– |
No water penetration |
Pass |
Peel adhesion (anodized aluminum) |
N/m |
≥ 200 |
647.9 |
Shear adhesion (anodized aluminum) |
Rating 1 to 4Footnote (2) |
Rating 1 or 2 |
Rating 1 |
Flashing System |
Window Installation |
Unit |
Requirement |
Result |
---|---|---|---|---|
"FlashSealR® Foam Flashing Tape"Footnote (2) |
Flanged |
L/s-m2 |
≤ Benchmark |
0.087 |
BenchmarkFootnote (3) |
FlangedFootnote (4) |
L/s-m2 |
Report result |
0.22 |
"FlashSealR® Foam Flashing Tape" |
Boxed |
L/s-m2 |
≤ Benchmark |
0.052 |
Benchmark |
BoxedFootnote (5) |
L/s-m2 |
Report result |
0.12 |
Flashing System |
Window Installation |
Requirement |
Result |
---|---|---|---|
"FlashSealR® Foam Flashing Tape" |
Flanged |
No water entry |
Pass |
Benchmark |
Flanged |
No water entry |
Pass |
"FlashSealR® Foam Flashing Tape" |
Boxed |
No water entry |
Pass |
Benchmark |
Boxed |
No water entry |
Pass |
Applied Pressure (Pa) |
Water Entry Rate (mL/min) |
Requirement |
Result |
||
---|---|---|---|---|---|
Benchmark |
"FlashSealR®" |
Benchmark |
"FlashSealR®" |
||
0 |
4 |
12 |
No water entry beyond the sill or to the stud cavity. No accumulation of water on the sill. |
Pass |
Pass |
50 |
5 |
9 |
Pass |
Pass |
|
80 |
4 |
17 |
Pass |
Pass |
|
160 |
14 |
14 |
Pass |
Pass |
|
310 |
14 |
25 |
Pass |
Pass |
|
520 |
17 |
31 |
Pass |
Pass |
|
730 |
18 |
60 |
Pass |
Pass |
Applied Pressure (Pa) |
Water Entry Rate (mL/min) |
Requirement |
Result |
||
---|---|---|---|---|---|
Benchmark |
"FlashSealR®" |
Benchmark |
"FlashSealR®" |
||
0 |
6 |
11 |
No water entry beyond the sill or to the stud cavity. No accumulation of water on the sill. |
Pass |
Pass |
50 |
6 |
11 |
Pass |
Pass |
|
70 |
7 |
12 |
Pass |
Pass |
|
150 |
11 |
13 |
Pass |
Pass |
|
310 |
13 |
24 |
Pass |
Pass |
|
520 |
16 |
26 |
Pass |
Pass |
|
720 |
19 |
40 |
Pass |
Pass |
Applied Pressure (Pa) |
Water Entry Rate (mL/min) |
Requirement |
Result |
||
---|---|---|---|---|---|
Benchmark |
"FlashSealR®" |
Benchmark |
"FlashSealR®" |
||
0 |
5 |
9 |
No water entry beyond the sill or to the stud cavity. No accumulation of water on the sill. |
Pass |
Pass |
60 |
8 |
19 |
Pass |
Pass |
|
80 |
10 |
17 |
Pass |
Pass |
|
160 |
10 |
20 |
Pass |
Pass |
|
310 |
15 |
21 |
Pass |
Pass |
|
520 |
18 |
24 |
Pass |
Pass |
|
720 |
21 |
45 |
Pass |
Pass |
Applied Pressure (Pa) |
Water Entry Rate (mL/min) |
Requirement |
Result |
||
---|---|---|---|---|---|
Benchmark |
"FlashSealR®" |
Benchmark |
"FlashSealR®" |
||
0 |
13 |
3 |
No water entry beyond the sill or to the stud cavity. No accumulation of water on the sill. |
Pass |
Pass |
50 |
14 |
5 |
Pass |
Pass |
|
80 |
15 |
7 |
Pass |
Pass |
|
150 |
16 |
6 |
Pass |
Pass |
|
310 |
16 |
8 |
Pass |
Pass |
|
520 |
17 |
9 |
Pass |
Pass |
|
700 |
18 |
10 |
Pass |
Pass |
Applied Pressure (Pa) |
Water Entry Rate (mL/min) |
Requirement |
Result |
||
---|---|---|---|---|---|
Benchmark |
"FlashSealR®" |
Benchmark |
"FlashSealR®" |
||
0 |
13 |
3 |
No water entry beyond the sill or to the stud cavity. No accumulation of water on the sill. |
Pass |
Pass |
50 |
16 |
8 |
Pass |
Pass |
|
80 |
15 |
12 |
Pass |
Pass |
|
160 |
13 |
14 |
Pass |
Pass |
|
310 |
15 |
16 |
Pass |
Pass |
|
510 |
17 |
18 |
Pass |
Pass |
|
720 |
19 |
19 |
Pass |
Pass |
Applied Pressure (Pa) |
Water Entry Rate (mL/min) |
Requirement |
Result |
||
---|---|---|---|---|---|
Benchmark |
"FlashSealR®" |
Benchmark |
"FlashSealR®" |
||
0 |
10 |
15 |
No water entry beyond the sill or to the stud cavity. No accumulation of water on the sill. |
Pass |
Pass |
50 |
11 |
19 |
Pass |
Pass |
|
80 |
14 |
20 |
Pass |
Pass |
|
150 |
12 |
17 |
Pass |
Pass |
|
320 |
13 |
18 |
Pass |
Pass |
|
520 |
15 |
22 |
Pass |
Pass |
|
710 |
18 |
22 |
Pass |
Pass |