Language selection

Search

Content page

From [Institution name]

Results of Testing the Product to the CCMC Technical Guide for Air Barrier Materials

Test

Requirement

Result

Five 1-m2-membrane specimens tested and measured for air permeance at a minimum of six air pressure differentials (DP) between 0 and 250 Pa

unconditioned specimens

≤ 0.02 L/(s·m2)

0.0001 L/(s·m2)

Five 1-m2-membrane specimens tested and measured for air permeance at a minimum of six air pressure differentials (ΔP) between 0 and 250 Pa

conditioned specimens

Where less than 0.01 L/(s·m2) for unconditioned specimens, the air leakage rate for conditioned specimens must not increase by more than 0.001 L/(s·m2) at 75 Pa pressure difference.

Pass

Water vapour transmission

exfiltration direction

Report value

2.7 ng/(Pa∙s∙m2)

infiltration direction

Report value

0.7 ng/(Pa∙s∙m2)