| Property | Unit | Requirements |
|---|---|---|
| Measured thickness sheet–overall | mm | 1.016 |
| Tensile strength | MPa | ≥ 9.0 |
| Dynamic puncture resistance | -- | Pass @ 5 J |
| Static puncture resistance | -- | Pass @ 20 kg |
| Elongation ultimate | % | ≥ 300 |
| Tensile set | % | ≤ 10 |
| Tear resistance | kN/m | ≥ 26.27 |
| Brittleness point | °C | –45 |
| Ozone resistance, on cracks | -- | Pass |
| Heat aging - tensile strength | MPa | 8.3 |
| Heat aging - elongation, ultimate | % | ≥ 200 |
| Heat aging - tear resistance | kN/m | ≥ 21.9 |
| Heat aging - linear dimensional change | % | ≤ ± 1 |
| Water absorption | mass % | ≤ +8, –2 of original |
| Weather resistance - visual inspection | -- | No cracks or crazing |
| Weather resistance - PRFSE Footnote (1) | % | ≥ 30 |
| Weather resistance - elongation, ultimate | % | ≤ 200 |