Content page
From [Institution name]
Property | Unit | Requirements |
---|---|---|
Measured thickness sheet–overall | mm | 1.016 |
Tensile strength | MPa | ≥ 9.0 |
Dynamic puncture resistance | -- | Pass @ 5 J |
Static puncture resistance | -- | Pass @ 20 kg |
Elongation ultimate | % | ≥ 300 |
Tensile set | % | ≤ 10 |
Tear resistance | kN/m | ≥ 26.27 |
Brittleness point | °C | –45 |
Ozone resistance, on cracks | -- | Pass |
Heat aging - tensile strength | MPa | 8.3 |
Heat aging - elongation, ultimate | % | ≥ 200 |
Heat aging - tear resistance | kN/m | ≥ 21.9 |
Heat aging - linear dimensional change | % | ≤ ± 1 |
Water absorption | mass % | ≤ +8, –2 of original |
Weather resistance - visual inspection | -- | No cracks or crazing |
Weather resistance - PRFSE Footnote (1) | % | ≥ 30 |
Weather resistance - elongation, ultimate | % | ≤ 200 |